SYS-210P-FRDN6T

2U Short Depth IoT Server. Single Socket P+ (LGA-4189) 3rd Generation Intel® Xeon® Scalable Processors

Anewtech Supermicro Server Singapore Edge Server SuperServer-SYS-210P-FRDN6T Rackmount Server

Features

  1. Single Socket P+ (LGA-4189) 3rd Generation Intel® Xeon® Scalable Processors
  2. 8 DIMM slots; Up to 2TB 3DS ECC DDR4-3200: RDIMM/LRDIMM/Intel® DCPMM
  3. Up to 2 PCI-E 4.0 FHHL & 2 HHHL expansion slots for Accelerator Add-On-Cards
  4. Onboard 2x 10GbE ports & 4x 1GbE ports
  5. 2x Internal 2.5" drive bays for SATA drives
  6. Redundant 600W DC -48V Power Supplies
  7. Ultra short depth, 2U Front I/O Edge Server

Specification

Anewtech Edge Server SuperServer SYS-210P-FRDN6T Supermicro Singapore Server

Product SKUs
SYS-210P-FRDN6T SuperServer SYS-210P-FRDN6T (Silver/Black)
Motherboard Super X12SPM-LN6TF
Processor
CPU Single Socket P+ (LGA-4189)
3rd Gen Intel® Xeon® Scalable processors
Support CPU TDP 85-270W
Please contact us for supporting conditions of high power (TDP >205W) processors.
Cores Up to 36C/72T; Up to 60MB Cache
System Memory
Memory Memory Capacity: 8 DIMM slots
Memory Type: 3200MHz ECC DDR4 RDIMM/LRDIMM
Memory Voltage 1.2 V
Error Detection ECC
On-Board Devices
SATA SATA3 (6Gbps); RAID 0/1 support
Chipset Intel® C621A
Network Connectivity 2x 1/10GbE port(s); 4x 1GbE port(s)
IPMI Support for Intelligent Platform Management Interface v.2.0
IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
Input / Output
USB 2 USB 2.0 port(s) (2 front)
2 USB 3.0 port(s) (2 front)
Video 1 VGA port(s)
Serial Port 1 COM Port(s) (1 rear)
Management
Software SUM
SSM
Redfish API
IPMI 2.0
Intel® Node Manager
SPM
KVM with dedicated LAN
NMI
Watch Dog
SuperDoctor® 5
Power Configurations ACPI Power Management
PC Health Monitoring
CPU Monitors for CPU Cores, Chipset Voltages, Memory
FAN Fans with tachometer monitoring
Pulse Width Modulated (PWM) fan connectors
Status monitor for speed control
Temperature CPU thermal trip support, PEPI
Monitoring for CPU and chassis environment
Chassis
Form Factor 2U Rackmount
Model CSE-211M
Dimensions and Weight
Height 3.5" (88.9mm)
Width 17.2" (436.88mm)
Depth 11.8" (298.8mm)
Package 7.4" (H) x 19.3" (W) x 23.3" (D)
Weight Net Weight: 17 lbs (7.7 kg)
Gross Weight: 22 lbs (10 kg)
Available Color Silver/Black
Front Panel
Buttons Power On/Off 
UID button
LEDs HDD activity
LAN1 activity
LAN2 activity
Power status
System information
Expansion Slots
PCI-Express (PCI-E) Slot 1: PCIe 4.0 x16 or x8 slot (low profile)
Slot 2: PCIe 4.0 x16 x8 slot (low profile will be disabled if slot 1 is configured as PCIe 4.0 x16)
Slot 3: 1 PCI-E 4.0 x8 FHHL (optional if CPU is less than 165W with 1U heat sink)
Slot 5: 1 PCI-E 4.0 x16 FHHL
Slot 6: 1 PCI-E 4.0 x16 FHHL
Drive Bays / Storage
Hot-swap 2x 2.5" hot-swap SATA drive bays
M.2 1 M.2 NVMe OR 1 M.2 SATA3
M-Key, 2280/22110
System Cooling
Fans 4 heavy duty fans with optimal fan speed control
Power Supply 600W Redundant DC -48V Power Supplies with PMBus
Total Output Power 600W : (-44) - (-65) Vdc
Dimension (W x H x L) 54.5 x 40 x 220 mm
+12V Max: 50A
5V SB Max: 3A / Min: 0A
Operating Environment
Environmental Spec. Operating Temperature: 0°C ~ 35°C (32°F ~ 95°F)
Non-operating Temperature: -40°C to 70°C (-40°F to 158°F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)